Numbers
- Predicted body weightHeight and sex, then the 6 mL/kg figure as arithmetic.
- P/F ratioWhere the ratio sits in the Berlin oxygenation bands.
- Rapid shallow breathing indexThe index next to the Yang and Tobin landmark of 105.
- Static complianceTidal volume divided by plateau pressure minus PEEP.
- Airway resistanceThe gap between peak and plateau, divided by flow.
- Cylinder duration estimateA conventional estimate of minutes left in an E or H cylinder.
- Minute ventilationTidal volume times rate, in liters per minute.
- Acid-base compensation checkpH, PaCO2, and bicarbonate, in that order.
Situations
The peak pressure is high
- Compare peak pressure with plateau pressure before changing the tidal volume.
- A sudden gap between them points at the circuit, the tube, biting, secretions, or bronchospasm.
- A high plateau points at stiffness or volume. Silencing the alarm is not the same as finding the cause.
The saturation fell
- Look at the person and the probe before trusting the number.
- Note the device and flow already in use, and whether the saturation changed after that device.
- A blood gas, if you have one, can be read as a P/F ratio. The ratio does not choose the next device.
The person looks worse than the gas
- A gas is one sample. Look at the rate, the work of breathing, and whether the saturation matches the story.
- Read pH, then PaCO2, then bicarbonate. A normal pH can still hide two abnormal values.
- The sample does not outrank the person in the bed.